Stadium lighting design requirements Stadium lighting standard value

Stadium lighting design requirements Stadium lighting standard value

Basketball, volleyball sports lighting standard value

1, the size of the venue. Basketball: 19 m × 32 m (PPA: 15 m × 28 m), volleyball: 13 m × 22 m (PPA: 9 m × 18 m).

2, the best location of the camera: The main camera is located on the vertical axis of the venue perpendicular to the standard height of 4 ~ 5 m. Secondary camera located in the goal, edge, bottom line of the back.

3, the computing grid is 2 m × 2 m.

4, the best measurement grid 2 m × 2 m, the maximum is 4 m.

5, Summary: As athletes look up from time to time, should be avoided to see the parallax between the ceiling and lighting.

6. The International Federation of Amateur Basketball (F.I.B.A) stipulates that a stadium with a total area of 40m × 25m for an international competition for television broadcasting shall be held for new sports facilities and its normal vertical illumination requirement shall not be less than 1500 lx. Lighting (ceiling polished) should be arranged to avoid glare to athletes and spectators.

7, Evmai - the main camera vertical illumination; Evsec - sub-camera vertical illumination; PPA - the venue.

FV.B requires a stadium of 19 m × 34 m (PPA: 9 m × 18 m) with a minimum vertical illumination of 1500 lx in the direction of the main camera.

Purcell Pavilion at the Joyce Center University of Notre Dame • South Bend, IN.jpg

Badminton sports lighting standard value

1, the size of the venue. PPA: 6.1 m × 13.4 m, TPA: 10.1 m × 19.4 m.

2, the best camera Location: The main camera is located in the back of the stadium, a height of 4 ~ 6 m, 12 ~ 20m from the bottom line. The secondary camera is close to the serve line, one on each side, for situations such as slow-motion playback, etc., on the floor behind the court edge.

3, the computing grid is 2 m × 2 m.

4, the measurement grid is best 2 m × 2 m, the maximum is 4 m × 4 m.

5, for badminton hall lighting principles are summarized as follows: Each table in the illumination value of two. The value to the left of the slash is the standard PPA illuminance and the value to the right of the slash is the luminance of the entire site (TPA). PPA can not be shaded. In order to provide a darker background, the shuttlecock has a better contrast and the overall floor illumination can be lower than the PPA illumination. Due to the athlete's request of looking up, it is recommended that no lighting be provided on the upper and rear of the PPA.

6, I.B.F. For major international competitions, ceiling / lighting fixtures should be installed at a height of at least 12m (over the entire PPA). The space between the two courses is at least 4m.

2_1045042382.jpg